Hot Rads in the Summer only 2 faults cause this
Просмотров 1277 часов назад
HOT rads in the Summer WHAT? You may notice the TOP of the radiator is WARM and the heating is OFF, there are only 2 causes. 1. The boiler has been used for hot water for a long time and it’s gone into "Pump Overrun” mode to cool down to 59C Every system requires an EXTERNAL auto by pass, often NOT done, it’s COMPULSORY to stop this fault and to keep the boiler temperature low for condensing mo...
Make your radiators more efficient
Просмотров 5816 часов назад
Avoid expensive breakdowns in the WINTER! Most installers charge a lot lot more because bad weather = less Jobs higher costs to YOU. Installers a “Boiler check” is FROM £100.00 “Boiler Service” FROM £150.00 [Don’t be too cheap!!!] Easy check the rads. I show you how. Turn the room stat to 22C does the boiler work? NO, check the Programmer is it on 247 / constant? Boiler displays fault or error ...
Why business £ail. 3
Просмотров 7921 час назад
Want to start your own business? Skilled trades person, market stall or shop, this video will guid and show what’s needed to succeed. Most businesses fail within 2 years avoid these situations Every business HAS to evolve to keep customers and get new ones. Location : Rent : Find new customers : Sponsor events : all is explained I show you after 50 years i’am still here and love it, can’t wait ...
Heating and controls installers take these 2 books with you.
Просмотров 10921 день назад
Heating faults can be a nightmare to find we can’t remember all the answers or sequence, the yellow “Fault Finding" Book or APP is for YOU made easy Most of the error codes are in the F.22 app, the book has charts and lists to find the fault sooner and stress free. The orange "Wiring Controls" Book has most of the popular drawings in COLOUR very easy to follow and find the fault. Mid Poz. Y Pla...
Jasna Góra Krakow
Просмотров 5021 день назад
If you are coming to Poland a “must do” is Krakow and Jasna Góra. In this video I will show you where to fly and stay to maximise your time. Pilgrims WALK from their home to the Monastery at least once in their life, some do this every year. Krakow must be one of the most beautiful cities in the world, accommodation from Hostels B&Bs Hotels and AirB&B. Tours to Wieliczka Salt Mine is a must, am...
How to CHANGE the boiler FLOW temp. To 60c Increase efficiency YOU make money.
Просмотров 10528 дней назад
This video will show you how to down rate the boiler temperature flow also how to do a “Heatloss” calculation in the Lounge to install a new BIGGER rad with a BALANCING TRV, external auto by pass may also needed for greater efficacy you make £££££. Get the picture. Installers, when you have to call to see a system, you know the boiler make / model find out before how to change the FLOW temp. To...
Increase your INCOME use the “Heatloss” APP. Independent advice on domestic central heating,
Просмотров 62128 дней назад
Normally an experienced heating installer has to do this complicated task. This video will show you how to check the radiator output at a flow of 60C not 75C which would make the return 40C and the boiler condenses 247 (saves MONEY) Recommend a larger lounge rad and move that one to another room. The result is a WARMER home for LESS money and I made lots more money as well. Win Win! This also m...
STOP don't call me in December for a boiler service
Просмотров 12428 дней назад
Your guarantee requires annual check, do it in the summer NOT at Christmas. EVERY heating system should be TESTED thru the summer months to check the valves and stats are working correctly and efficiently. Summer is also best for upgrading CONTROLS Our Videos, books and APPs are perfect for installers who have little experience or confidence. ☀︎ ☀︎ ☀︎ ☀︎ ☀︎ ☀︎ ☀︎ ☀︎ ☀︎ ☀︎ ☀︎ ☀︎ ☀︎ ☀︎ ☀︎ ☀︎ ☀︎ ☀...
Make money by FIXING heating faults No experience necessary teach yourself, easy course
Просмотров 782Месяц назад
EASY to follow videos will take you from zero to hero. Lots of advice from my 45 years on the tools. How to test Pumps : Fans : Sensors & Stats : Sequence of operation and all you need to start CENTRAL HEATIG FAULT FINDING There will always be a shortage because no-one want to to this job We are the most over paid manual skilled workers, if you can fix heating faults or just service there will ...
Combi boiler + 2 zones is easy, I did it in the 1980’s. Let me show you how…
Просмотров 174Месяц назад
Don’t just think a large system is a big 30KW boiler 2 / 3 zone’s and a big vented cylinder. A large 3 bed with a separate shower UT or extension that system would be expensive to install and running cost. Location is most important, as close to the bathroom or mid way to the kitchen is most efficient, consider water draw off and gas wastage over 12 years. Short pipe runs make more profit for t...
Boiler "Gas Rate" & "Gas Pipe" test is easy, I show you how
Просмотров 6972 месяца назад
Every time a new boiler or any gas appliance is installed the "GAS PIPE SIZE" has to be calculated to make sure it's correct and safe. If the boiler stays ON for long periods it could be UNDER gassed thus high fuel bill will follow. We must also test the "GAS FLOW RATE" to the manufacturer requirements to prove 100% efficiency (often not done) thus not safe and expensive. Only a Gas Safe Regist...
Need a new boiler? Before you install or start looking watch this video.
Просмотров 2042 месяца назад
My Hints & Tips may save you a lot of time and money. Your boiler with correct maintenance should last for over 12 years, location is most important, the further from the taps the higher the running cost of water and GAS. Every gas appliance MUST be checked EVERY year for safety and efficiency. The guarantee T&C's will demand this done or it’s cancelled. Every year the heating water must be ana...
How to become self employed NEXT STEP video 2.
Просмотров 1192 месяца назад
Are you UNDER PAID under valued and OVER WORKED? These videos will guid and show what’s needed to succeed. Most businesses fail within 2 years because of basic knowledge of administration and expansion. Every firm HAS to evolve to keep customers and get new ones. It does not matter If you have 300 branches or 10 staff or self employed it’s the same system. I explain how after 50 years i’am stil...
How to become self employed easy guide promo video 1.
Просмотров 1352 месяца назад
Are you UNDER PAID under valued and OVER WORKED? These videos will guid and show what’s needed to succeed. Most businesses fail within 2 years because of basic knowledge of administration and expansion. Every firm HAS to evolve to keep customers and get new ones. It does not matter If you have 300 branches or 10 staff or self employed it’s the same system. I explain how after 50 years i’am stil...
Boiler Preheat on or off?
Просмотров 9063 месяца назад
Boiler Preheat on or off?
Boiler Pumps Faults 2
Просмотров 2503 месяца назад
Boiler Pumps Faults 2
Boiler Efficiency Chart. Is it time to change or keep? The answer is here. Easy to Follow.
Просмотров 713 месяца назад
Boiler Efficiency Chart. Is it time to change or keep? The answer is here. Easy to Follow.
Boiler 4 Part Electrical Test - Made Easy
Просмотров 3733 месяца назад
Boiler 4 Part Electrical Test - Made Easy
Boiler Pump Faults Part 1
Просмотров 1,2 тыс.3 месяца назад
Boiler Pump Faults Part 1
Boiler RF Controls All you need to know “Easy to Follow” course 24 04 12
Просмотров 2464 месяца назад
Boiler RF Controls All you need to know “Easy to Follow” course 24 04 12
Boiler RF Controls ProMo 24 04
Просмотров 1444 месяца назад
Boiler RF Controls ProMo 24 04
Central Heating Boiler Faults BOOK (easy to follow) took me 45 years to write
Просмотров 51 тыс.4 месяца назад
Central Heating Boiler Faults BOOK (easy to follow) took me 45 years to write
Noisy FAN does it Purr? This video will show you how to test it and the 2 APPs you need. 11 Mar 24
Просмотров 2215 месяцев назад
Noisy FAN does it Purr? This video will show you how to test it and the 2 APPs you need. 11 Mar 24
Check the loft tanks EVERY year. You will be AMAZED
Просмотров 1585 месяцев назад
Check the loft tanks EVERY year. You will be AMAZED
You Tube ProMo 3
Просмотров 635 месяцев назад
You Tube ProMo 3
In the UK why are we still install 1960’s analog room stats? 29 02 24
Просмотров 1225 месяцев назад
In the UK why are we still install 1960’s analog room stats? 29 02 24
Balance Heating system with NO tools or NO Skill 16 02 24
Просмотров 1,4 тыс.6 месяцев назад
Balance Heating system with NO tools or NO Skill 16 02 24
Wanted: Central Heating Installers & Breakdown Engineers TODAY 24 01
Просмотров 7486 месяцев назад
Wanted: Central Heating Installers & Breakdown Engineers TODAY 24 01
A Cold rad fault is either AIR or a faulty TRV. Version 2: 24 01
Просмотров 9 тыс.7 месяцев назад
A Cold rad fault is either AIR or a faulty TRV. Version 2: 24 01

Комментарии

  • @davidadiwego4608
    @davidadiwego4608 12 часов назад

    My Danfoss HW/CH controller is located in a quite awkward position (low in airing cupboard) which makes it difficult for me to bend down to and see it. I like to put HW on as and when I need it, so I need to regularly access the controller. I want to relocate the controller a few feet outside the cupboard to a much more convenient position. Before anyone asks, no, me hiring a professional to do the job is not an option due to cost. Basically, I need to (safely) extend the wiring (making sure each channel wire-extension goes to the right place in the controller, yes? What's the proper stuff (wire and connectors) I need for the job....Anybody?

    • @mrcombiBedford
      @mrcombiBedford 11 часов назад

      Hi David, thanks for asking, controls wiring is not for DIY because you are messing with 230vAC which is dangerous. Please trying find someone who has a certificate of attending a course, shop around there not all expensive maybe pay by instalments. I have seen your installation too many times, (I used to charge £200 to rewire now its £300+) 1st power OFF to remove the cover take lots of fotos which terminal has which colour wire, do the same with any junction boxes, Start with the easiest PUMP wire where does that go? Make a drawing, Cylinder / room stats do the same, Look at my VIDs on wiring a room stat Y / S Plans, have the book or get the APP. Big danger is BLUE neutral wire are they being used with voltage, if so that MUST be rewired, not allowed and dangerous. If the programmer is over 8 years consider 2 channel RF, see my VID. that is easy and will save you money more controllable HW & CH.good luck, George Staszak 😀👍

    • @davidadiwego4608
      @davidadiwego4608 7 часов назад

      @@mrcombiBedford I know how and why to cut the power. never mind

    • @mrcombiBedford
      @mrcombiBedford 6 часов назад

      @@davidadiwego4608 No problem👍

  • @prawnk1ng
    @prawnk1ng 2 дня назад

    There is another fault. I wonder if anyone else can figure it out.

  • @adamkay60
    @adamkay60 6 дней назад

    Hello, great video, but can you show testing the voltage going to the gas valve, as on some boilers I find it almost impossible to get the probes of my multi meter to make a good contact. Thanks, Adam

    • @mrcombiBedford
      @mrcombiBedford 5 дней назад

      Hi Adam, thanks for that and you are correct too many boiler parts are fitted badly making testing very difficult or even worse difficult to replace, but no one listens to me. What I did was to order new meter leads with very thin probes (BG engineers have them) shop around, shorten the metal probes to 10mm just enough to fit on the PCB connection which is where I did all the testing not on the component, much easier and faster. Hope that helps, may do a video on this.🤩👍

    • @adamkay60
      @adamkay60 5 дней назад

      @@mrcombiBedford Thank you - yes it does help and I’ll follow your advice. Btw I came and did your fault finding and wiring courses quite a few years ago when I first started - both very good - I might come and do the fault finding one again sometime as I think I’d get more out of it now I know a bit more. All the best, Adam

    • @mrcombiBedford
      @mrcombiBedford 5 дней назад

      @@adamkay60 Hi Adam, I retired from training in September 22, to concentrate on Vids and APPs have a look mrcombi.com

  • @richardharris5858
    @richardharris5858 7 дней назад

    As always great advice. Got the books in the van just in case. 🤔😅

    • @mrcombiBedford
      @mrcombiBedford 7 дней назад

      Dear Richard, Thanks you for your custom very glad to help, all the best, George staszak. 😍👍

  • @IncredibleMet
    @IncredibleMet 19 дней назад

    Hi George, Are the apps working again?

    • @mrcombiBedford
      @mrcombiBedford 18 дней назад

      Hi Met, thanks for asking, yes all are working ready to download, we are still doing updates with new icons to comply with new T&Cs from both stores, please use the link for APPs and books. take care George Staszak Our APPs are all one price £4.99 no vat www.mrcombi.com/apps/ Apple iOS download: apps.apple.com/gb/developer/m... Google Play download: play.google.com/store/search?... BOOKS: www.mrcombi.com/shop/

  • @kamilpilawski4601
    @kamilpilawski4601 23 дня назад

    Thank you, sir!

    • @mrcombiBedford
      @mrcombiBedford 23 дня назад

      Cześć Kamil, thanks for the comment glad you liked it, the Krakow video is due next week, please subscribe for notifications, all the best. Jerzy 🤩👍

  • @shubhambadgujar9943
    @shubhambadgujar9943 25 дней назад

    sir I have a question, this aqua signal ignites the gas boiler but is it a continous signal or just a one time ? the reason i am asking this is , i am doing a project and i have connected a electric heater to heat water but i dont want to run both heaters at same time and want to save my gas money so i figured if i just block this aqua signal , i can stop gas boiler from igniting ! so please if you reply it will be a huge help ! thanks in advance!!

    • @mrcombiBedford
      @mrcombiBedford 24 дня назад

      Hi, thanks for asking, All combies have 2 switches 1 for HW and 1 CH which are NO (normal open) dead, until a tap is turned ON. There are only 2 ways to start ignition 1 sensor (Ohms) the PCB see's a change and starts up, or 2 a switch is activated from NO the NC (normally closed) and the boiler starts up until the tap is turned OFF then back to NO shuts down. I don't understand why you want to connect an ELX heater as it's 3 times more expensive than Gas? You can just unplug the aqua sensor from the PCB and enjoy big bills. If you want at add HW cylinder see my video on add 2 zones to a combi or any boiler. hope the helps, George 🤩👍

  • @madmaycon2531
    @madmaycon2531 27 дней назад

    Without a doubt it is an excellent app, it helps me a lot.

  • @mohitl1697
    @mohitl1697 27 дней назад

    and how do you feel in an era of 'Smart TRV's' - eg the HIVE / Honeywell digital ones

    • @mrcombiBedford
      @mrcombiBedford 25 дней назад

      Hi again, Smart TRVs are very expensive Amazon £274.00 for 5 heads is completely unnecessary because the payback cost will never happen, EVERY rad needs one, just like Air source / Solar and EVs 👍 Smart controls 100% save money balancing TRVs, Heat loss of the home / lounge 60c flow is the way to save money. Why some people spend 1000's to save what? When I added what I paid into my pension I have to be 117 before I make £1.00 profit. I paid for their big building and bonus. Hope the helps, George 😀👍😤

    • @mohitl1697
      @mohitl1697 25 дней назад

      @@mrcombiBedford okay. lastly one more question. if you have smart thermostat in hallway and radiator, you said it should be fitted with a trv. i was under the impression area with thermostat shouldnt be fitted with trv. otherwise both will compete, and also there is no 'bypass' for the boiler incase other smart trv's are off when the heating might be commanded

    • @mrcombiBedford
      @mrcombiBedford 25 дней назад

      @@mohitl1697 Hi Again, no problem, as always every rad needs a TRV if the stat is in the hall a TRV must still be there, in a ROOM not allowed both. Ignore what is in the boiler has fitted, as I say many times the rules and Codes of Practice and CONTROLS firms demand an external auto by pass on EVERY system. It's the CONTROLS firms demand an external by pass NOT the boiler manufacturer. Installers wrongly keep thinking it's a boiler requirement when it's not. take care, George 🤩👍

  • @mohitl1697
    @mohitl1697 27 дней назад

    What about Sentinel X1000?

    • @mrcombiBedford
      @mrcombiBedford 25 дней назад

      Hi, thanks for asking, the X100 or Fernox F1 are very good inhibitors I highly recommend refilling with them if the system has been correctly. If not X200 or F2 are a more for problem solving, eg. noise or blockages pump problems which is often the case. Hope that helps, George 🤩

  • @DunkingJaffaCakes
    @DunkingJaffaCakes 29 дней назад

    2:47 Shame I can't see numbers 4 to 9 as they're covered by a thumbnail for the next video. 🤦‍♂

    • @mrcombiBedford
      @mrcombiBedford 29 дней назад

      Hi, Jaffa, we all live and learn, thanks for the comment, George 🤩

  • @groovejet33
    @groovejet33 Месяц назад

    Short circuit test... Shouldn't the reading be over 20 ohms 🤔 If under 20 ohms, then there may be a fault on a component...like fan or Pump 🤔😉

    • @mrcombiBedford
      @mrcombiBedford Месяц назад

      Hi 33, thanks for asking, over because we have to have a HIGH resistance to stop fuses blowing, 100 Ohms is the standard value that we work to. It should be O.L. (over 1 million) but some firms don't use the PCB the same way. Hope that helps, George 🤩👍

    • @groovejet33
      @groovejet33 Месяц назад

      @@mrcombiBedford thankyou

  • @nickpage4333
    @nickpage4333 Месяц назад

    If it's that good no more heating engineers

    • @mrcombiBedford
      @mrcombiBedford Месяц назад

      Hi Nick, thanks for comment, because of a shortage of engineers who get richer and richer this will only get worse for customers. No one wants to do this job, shame. all the best, George 😍

  • @dickiedubs3137
    @dickiedubs3137 Месяц назад

    Hertz.....I don't understand either

    • @mrcombiBedford
      @mrcombiBedford Месяц назад

      Hi Dickie, thanks for asking, Hz is not just used as a radio or TV frequency but it's the best way to measure a pump / fan or anything that moves. I found Vaillant publish lots of data in Hz. A pump can be 2K revs but we can't measure revs. but we can in Hz. which is 100% accurate. Most will use Ohms and volts which is OK but Hz is faster and more accurate . Hope the helps, take care George 🤩👍

  • @derickdoig4008
    @derickdoig4008 Месяц назад

    This is a horrible idea.

    • @mrcombiBedford
      @mrcombiBedford Месяц назад

      Hi Derick, thanks for your comment, take care George 👍

  • @michaelwalsh1023
    @michaelwalsh1023 Месяц назад

    13kw not enough for a house ? Enlighten me please ?

    • @mrcombiBedford
      @mrcombiBedford Месяц назад

      Hi Michael, just going to have lunch, a mid Poz. valve has a gap of about 18mm to the heating side, that only allows 13kw of rads, its recommended only 10kw because the big double K rads at the front of the house will not reach max temp 75C the result will be the boiler stays on much longer and high fuel bills. Remember it's the boiler RETURN stat that switches OFF the boiler. It's better to over size the rads with a LOWER return temp. use my "Heat loss App" and you will amazed at how many rooms have under sized rads 22mm Zone valve can have about 20kw of rads recommended max 18 better to split the system to 2 or more zones to lessen the boiler stress and much cheaper to run. Thanks for asking, Marmite crumpets are go! 🤩👍

  • @paularnell
    @paularnell 2 месяца назад

    I still love your videos George 🙏🏻

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      Thank you, I wanted a Knighthood should have baked a cake😘

    • @paularnell
      @paularnell 2 месяца назад

      😂

  • @paularnell
    @paularnell 2 месяца назад

    When you are mentioning gas pipe sizes, I think you will find it’s 35mm and not 34mm 👍🏻

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      Hi Paul, thank you very much I did not notice the error, take care, George 🤩👍

  • @olympusplumbingheating5027
    @olympusplumbingheating5027 2 месяца назад

    You apps mite be great but the videos still don’t play

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      They will do soon as all the bugs and updates are done next week, take care, George, 😄👌

  • @MartinMcIntosh-oz9dq
    @MartinMcIntosh-oz9dq 2 месяца назад

    Very informative

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      Hi Martin, thanks for feed back, all the best, George 🤩👍

  • @sauliusban
    @sauliusban 2 месяца назад

    Thank you Sir

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      Thanks for liking, take care, George 🤩

  • @WOFFY-qc9te
    @WOFFY-qc9te 2 месяца назад

    Mr Combi, great channel with sound information thanks. Can you help me with a solar thermal tank project. I have a Valiant Ecotec which is a cracking boiler, I am fitting a thermal solar tank. Now some boilers can take the preheated water in and top the temp up and others can't. A blend valve to limit the input temperature is suggested on some installations. Now can I feed my boiler from the tank or can I tie into the hot water pipes via a diverter that favours the solar if hot enough. Thanks for any info and thanks for you straightforward presentation.. Best.

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      Dear Woffy, Thanks for the kind words, not an expert in that field I would go to Vaillant for advice. Don't like air source or EV's I would never take any advice about heating or cars from a politician. All the best, George 🤩👍

  • @olympusplumbingheating5027
    @olympusplumbingheating5027 2 месяца назад

    Hi I have just bought the fault finding app from Apple app store and none of the videos play. How can I get a refund please. I have try emailing you from the app and the email was returned saying couldn’t find address

  • @olympusplumbingheating5027
    @olympusplumbingheating5027 2 месяца назад

    Is the fault finding book the same as the fault finding app because I use a tablet when I’m out on the job. Plus a few people have commented on the videos not working on the app has this now been fixed. Great content by the way

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      Thanks for the question, the book has a lot more information we always advice have both books and all the APPs. if you are an installer or breakdown engineer. The APP has 21 "How to" chapters the book has flow charts, No ignition and so on. The 2 video APPs are being updated hope to be finished in a couple of weeks, (the icons are amazing) Don't download until done, the other 6 will be next. All the best George Staszak 🤩👍

  • @TW-mp8zx
    @TW-mp8zx 2 месяца назад

    I love tea but unfortunately 99.9% of my customers tea goes back down their sinks...

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      As I said, don't drink in every house🤩👍

  • @DragonXDrei
    @DragonXDrei 2 месяца назад

    I wish you showed how to replace that old thermostat to the new o, and if we have to connect the same wiring, 2 live 1 neutral plus sensor.

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      Dear Gixxer, thanks for asking, I cannot show you how to wire a digital stat because each firm has different terminals, you would not change to the same type, 2L +N, all digital. have COM and SW.Live same goes for Open Therm. some will be 230vAC or 24vDC or Volt Free it depends on the one you buy, as in other Vids. if your boiler has O.T. that's the lowest running cost after that VF then 24vDC avoid 230vAC. hope that explains. Our Wiring book and APP has more info. take care, George Staszak 👍

  • @DinkyDoughnut
    @DinkyDoughnut 2 месяца назад

    I didn't know how to run a business despite having so many talents. I did also failed.!

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      Dear Kuldi, thanks for your comment, all the best, 🤩👍

  • @mdismailpdm
    @mdismailpdm 2 месяца назад

    Your video is very nice.🥰🥰🥰

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      Hi MD thank you very much for your comment 🤩

  • @sauliusban
    @sauliusban 2 месяца назад

    Where to get more information sir?

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      Hi Saulis, thanks for asking, I will be making more Vids. this month just Subscribe and click Notifications and enjoy, take care, George 😇👍

  • @alexandruleonarda.3673
    @alexandruleonarda.3673 2 месяца назад

    Interesting, as usual, I would like to know more. 🧐🤔

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      Dear Alex, thanks for asking, I will be making more Vids. this month just Subscribe and click Notifications and enjoy, take care, George

  • @gasservenw1369
    @gasservenw1369 2 месяца назад

    Hi George. Just sidetracking slightly but I have a customer who upgraded their Landis & Gyr roomstat to an RF EPH stat but didn't want the old stat removed. The installer set the old stat to max and told them not to use it but use new RF stat. This is correct as far as I'm aware but I think they have been moving stat probably due to habit. So, going to link wires behind stat just wanted to confirm which ones to link out. Thanks

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      Dear Gas NW, Thanks for asking, yes you are correct the old stat MUST be disconnected, I understand they don't want to remove the old one before decorating. Power OFF and remove the wires from the boiler end and make safe (don't cut them OFF, someone may want to reconnect them later). Hope that helps, George Staszak 🤩👍

    • @gasservenw1369
      @gasservenw1369 2 месяца назад

      @@mrcombiBedford Hi George. Many thanks for the information. Its an old heat only boiler so will I need to put a link back in on the boiler end so that the EPH twin channel programmer controls the switch live to the boiler? Thanks

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      @@gasservenw1369 Glad to help, it's only the feed to the old stat that needs removing at the boiler end as you say.👍

  • @ArcanePath360
    @ArcanePath360 3 месяца назад

    I feel my radiator nearest the boiler get slightly warm when running a hot bath. Is this normal for a combi? I think it's done it since I moved in 12 years ago

    • @mrcombiBedford
      @mrcombiBedford 3 месяца назад

      I think I replied earlier, but its the diverter letting by. thanks for asking, George

    • @ArcanePath360
      @ArcanePath360 3 месяца назад

      @@mrcombiBedford Thanks. Do you know if I should be worried, like maybe it's about to fail and I should get looked at or just carry on?

  • @billynomates920
    @billynomates920 3 месяца назад

    that's vaillant off my list then. my ideal has a preheat button which you press once and it puts preheat mode on - none of this press triangle square and x, hold left joystick down, count to ten, turn round and touch your toes nonsense.

  • @WOFFY-qc9te
    @WOFFY-qc9te 3 месяца назад

    Tinnitus, have had this for fifty years and it is my annoying friend !. Very important you don't focus on it, accept that it is there and get on with life. Mr Combi has given some good suggestions and I use these techniques to keep the tubes clear. The Eustachian tube is normally closed but opens when we swallow, yawn or chew. This allows air to get into the middle ear and any mucus to get out. This keeps the air pressure equal on either side of the eardrum. Having equal air pressure on each side of the eardrum - and the middle ear free of mucus - helps the eardrum to vibrate. This vibration is needed for us to hear properly. My analysis of some forms of. Tinnitus can be the reproduction of a tone which you have had long exposure to including something like a computer fan, for example you hear a constant tone in a space from something, the brain counters that like noise cancelling earphones and turns down the gain for that frequency. When you leave the space the brain no longer hears the tone and but is still cancelling the tone but as it is not there you hear what the brain is producing. Don't Focus on it and do speak with your Doctor about your hearing. Good luck I am taking my friend for a walk..... Good advice Mr Combi

  • @sajidlunat
    @sajidlunat 3 месяца назад

    Well done . Best explanation so far

    • @mrcombiBedford
      @mrcombiBedford 3 месяца назад

      Dear Sajid, thank you very mush for the kind words, take care, George Staszak 🤩👍

  • @JohnFitzsimmons-md3up
    @JohnFitzsimmons-md3up 3 месяца назад

    Any luck with the apps videos as yet ? Mines has been off line for a few months now. I even tried re-purchasing them with no luck

    • @mrcombiBedford
      @mrcombiBedford 3 месяца назад

      Hi John, thanks for your patients the APPs are moving up the system to finale build, I will email all when ready to re load, regards, George staszak

  • @jezlucas3878
    @jezlucas3878 3 месяца назад

    Hi what causes gas rate to be too high and over what manufacturer states

    • @mrcombiBedford
      @mrcombiBedford 3 месяца назад

      Hi Jez thanks for asking, its the gas valve, after a few years it get out of settings and often does not close promptly thus sues more gas. sometimes it just shuts down, dead. Often it's replaced with a different model same as PCBs, that's why I say after 4 years check the firm for updates. take care, George Staszak 🤩

    • @DanielGreen_690
      @DanielGreen_690 Месяц назад

      @@mrcombiBedfordHi George, I’ve literally been noticing this issue with Ideal Combi2 boilers. Mainly with the C24 model which when running gas rate checks seem to be sometimes about 3KW - 4KW overgassed. Maybe they have a gas valve issue with this model as these are relatively new. Also would a faulty PCB cause a higher gas rate?Thanks, Dan.

    • @mrcombiBedford
      @mrcombiBedford 29 дней назад

      @@DanielGreen_690 Morning Daniel, not the PCB, 1st. call the firm to report the issue feed back is vital to them and ask for guidance. I think just reset the GV come back after two weeks and retest / replace or it's OK. Many thanks for asking and have others had this common problem? Please leave a comment below, take care, George Staszak 🥰👍

  • @hayleymason7694
    @hayleymason7694 3 месяца назад

    This video is a life saver! I’m usually pretty good at figuring out stuff but I could not figure out how to set my heating timer to once a day! Thank you so much! ☺️

    • @mrcombiBedford
      @mrcombiBedford 3 месяца назад

      Many thanks for comment, glad to help, take care, George 🤩👍

  • @colindevine3233
    @colindevine3233 3 месяца назад

    I WISH I HAD SEEN THIS VIDEO A LONG TIME AGO , THANKYOU FOR YOUR VALUABLE INFORMATION !!!* :)

    • @mrcombiBedford
      @mrcombiBedford 3 месяца назад

      Dear Colin, thanks for the kind words, never too late, Polski saying, we learn all our lives and die stupid, take care, George Staszak 🤩

    • @colindevine3233
      @colindevine3233 3 месяца назад

      @@mrcombiBedford cheers man :)

  • @richardclarke9966
    @richardclarke9966 3 месяца назад

    "In my wife's house" 🤣. So true...

    • @mrcombiBedford
      @mrcombiBedford 3 месяца назад

      Hi Richard, that's 2 of us, take care, George 🤩👍

  • @raymondmajrowski4428
    @raymondmajrowski4428 4 месяца назад

    10.20am, good video, very informative. Question How do you work out the size of an expansion vessel. For instance a system with 17 radiators, mostly large, 3 zones, to 50 kw, commercial boiler, no expansion vessel present. Ray Majrowski. REM plumbing and heating. Thanks.

    • @mrcombiBedford
      @mrcombiBedford 4 месяца назад

      Hi Raymond, thanks for asking, The best place for advice is the boiler firm, officially we add all the water content of the rads, pipe and boiler, good luck. As its commercial which is not my world, I would expect between 20/30 ltr. would do, better over size than under. take care, George Staszak 🤩👍

  • @MagicianMan
    @MagicianMan 4 месяца назад

    Ideal sell their own - for our Heat Only Boiler with S Plan Plus its over £500 for the Controls & 2 Zone Extension Kit - just ridiculous!

    • @mrcombiBedford
      @mrcombiBedford 4 месяца назад

      Thanks for tell me, that is an offer to avoid, that is nearly the price of a boiler, this video came just in time. Take Care George Staszak 🤩👍

  • @johnnyarmstrong2695
    @johnnyarmstrong2695 4 месяца назад

    Thank you

    • @mrcombiBedford
      @mrcombiBedford 4 месяца назад

      Dear Jonny, thank you for the kind comment, all the best, George Staszak 🤩👍

  • @user-iy8vq4mj7s
    @user-iy8vq4mj7s 4 месяца назад

    Yr information is clear n prompt and trust me your a very good teacher in explaining thanks

    • @mrcombiBedford
      @mrcombiBedford 4 месяца назад

      Thank you very much for the lovely comment, all the best George Staszak 😍👍

  • @availablerooms-wortingroad4587
    @availablerooms-wortingroad4587 4 месяца назад

    Thanks for this helpful video but in the places (8 mins 35 seconds onwards) where you talk about the blue wire, we can't see the wiring mistake you are referring to in the video and the discussion about the blue wire is not clear. Could you please show the wiring of the old thermostat that has been done incorrectly and the new correct way for a digital thermostat. I have just installed a digital one(Siemens RDH100) and I used only the yellow and red cable because those were used in the old Honeywell I was replacing. The blue wire was already cut off but not sleeved or taped up. I replaced the Honeywell because I was suspicious that it was not turning the heating off in time. So potentially overshooting and strangely it was also not turning on the heating early enough either.

    • @mrcombiBedford
      @mrcombiBedford 4 месяца назад

      Dear AR, thanks for asking, I have lots of drawings in other vids APPs and book, that shows what you are asking. The old 230vAC room stat has to have 3 wires, the neutral we don't need in digital stats so we make it safe and use the other two as they are Com and SW.L. Hope that helps, George 👍

    • @availablerooms-wortingroad4587
      @availablerooms-wortingroad4587 2 месяца назад

      @@mrcombiBedford Thank you very much George. I managed to get the thermostat installed using the 2 wires. I am experiencing that under the stairs location problem though. Even in June, the temperature under the stairs is dropping to 18 degrees, causing the heating to turn on. I think I need to configure it for a 2 degree differential so that it only switches the heating on when there is a 2 degrees difference. Thanks again.

    • @mrcombiBedford
      @mrcombiBedford 2 месяца назад

      Thanks for asking the blue wire is with the black wire that’s wrong All the blue wires should be together and never with others Hope that explains George

  • @mjidobelg315
    @mjidobelg315 4 месяца назад

    شكرا جزيلا لك

    • @mrcombiBedford
      @mrcombiBedford 4 месяца назад

      Dear Mjido, please translate to English, all the best, George

  • @IncredibleMet
    @IncredibleMet 4 месяца назад

    Hi George, If you don’t mind me asking, how come you don’t the in-person courses anymore? Could you recommend where I could go? I’ve just finished my MLP and while your books and apps are very helpful, I need some hands on experience. Many thanks

    • @mrcombiBedford
      @mrcombiBedford 4 месяца назад

      Dear Met, Thanks for your email, I have retired from training after 20 years to concentrate on RUclips videos, www.youtube.com/@mrcombiBedford/videos where I can reach more installers. Please subscribe to us and watch the Vids. They are made for you. We also have a load of APPs plus 2 book, for you or anyone in the heating industry. If you need “hands on” training then go to the firms, compulsory Baxi, Worcester Bosch, Vaillant plus my favourite is Intergas. For controls Drayton + (RUclips vids) + Honeywell Home. Takes Care George Staszak😍👍 Mr Combi Our APPs are all one price £4.99 no vat www.mrcombi.com/apps/ Apple iOS download: apps.apple.com/gb/developer/m... Google Play download: play.google.com/store/search?... BOOKS: www.mrcombi.com/shop/

    • @IncredibleMet
      @IncredibleMet 4 месяца назад

      @@mrcombiBedford Hi George. Many thanks for getting back to me. I’ve got the apps and have just ordered the books. I will hopefully be attending the manufacturers courses as you have advised once my ACS comes through. Drayton and Honeywell only do online from what I’ve seen. Many thanks

    • @mrcombiBedford
      @mrcombiBedford 4 месяца назад

      @@IncredibleMet Unfortunately that's the norm, it is very expensive to invite 12+ engineers and feed them etc. and a lots just don't turn up because the cost is too low. One firm told me of the 12 booked 3 came, a lot of food was wasted plus 2 Reps hotel bills. This is why they stopped. Take care, George

    • @IncredibleMet
      @IncredibleMet 4 месяца назад

      @@mrcombiBedford Hi George, I’m having issues with the apps. I’ve emailed the app support email. Would appreciate it if that can get sorted quickly so I can start learning! Many thanks

    • @mrcombiBedford
      @mrcombiBedford 4 месяца назад

      @@IncredibleMet Dear Met, We are still trying to find which code has been deleted, We have a plan B and I will get in get in touch. Thanks for waiting Sales 👍

  • @muwafaksaid5934
    @muwafaksaid5934 4 месяца назад

    Thank you very much, for a very kind explanation.

    • @mrcombiBedford
      @mrcombiBedford 4 месяца назад

      Dear Muwafak, thanks for the kind words, glad to help, take care, George Staszak 🤩👍

  • @kr173sh
    @kr173sh 4 месяца назад

    Hi, my hot water pump is constantly on even though the hot water and CH is off. I changed the motorised valve but the issue remains. Any idea? Thank you

    • @mrcombiBedford
      @mrcombiBedford 4 месяца назад

      Dear kr173sh, Thanks for asking, who told you to change the diverter and how did you test it? If the pump runs in HW the stat is still calling, see my videos on HW and Diverter faults and how to test parts. 🤩👍

    • @kr173sh
      @kr173sh 4 месяца назад

      @@mrcombiBedford the plumber said the micro switch was sticking and to change the valve. It worked for 2 weeks but can to square one.

    • @mrcombiBedford
      @mrcombiBedford 4 месяца назад

      Very good, excellent, now call him back to fix it, he is very good👍@@kr173sh

    • @aixalexander5257
      @aixalexander5257 Месяц назад

      ​@@mrcombiBedford should the water pump be on when you turn on hot water on the tap? (with the central heating off )

    • @mrcombiBedford
      @mrcombiBedford Месяц назад

      @@aixalexander5257 Hi Aix, I am not understanding your question "water pump" combies do not have water pumps. 🤔

  • @hikolanikola8775
    @hikolanikola8775 4 месяца назад

    how about, pump makes litteraly 0 noise? and still not working, not even the pipe hot water aint working which i supose does not relly on pump... wtf is wrong with that stupid thing... It starts burning, it starts heating water, then you can hear the switch and immediately shuts it down, and the 'sand clock' diode keeps blinking

    • @mrcombiBedford
      @mrcombiBedford 4 месяца назад

      Hi Nikola, Pumps and heating systems must NOT be tested in HW mode only in Heating, because it tests the diverter valve has moved and many boilers do not use the pump in HW. If the heating is OK then the FLOW pipe gets hotter, if not either call a breakdown engineer or factory Tech. Dept. All the best, George Staszak 👍